The 2-Minute Rule for Dp50rb

Get a complete and extended check out in the anatomical framework via panoramic imaging coupled with velocity indicator and forward/backward scan means generating scanning much easier, smoother and much more controllable.

Articles Strategy Check out the battery periodically : a) Look at if battery may be charged Commonly when power-on: That The existing ability is one hundred% or capacity increases right after a brief time suggests that the battery is usually billed normally.

Assessing individuals in currently’s demanding setting necessitates ground breaking technology that permits clinicians to create fast and assured diagnoses. The versatility on the DP-50 expands your clinical utility even though assisting to boost patient care.

Whenever you quit the scanning as well as picture seize, you must energy from the system and disconnect the procedure through the AC energy offer, then pull out AC electrical power cables. Web site 109: Battery Connecting Board

Permits utilization of numerous scanned angles to form one image, leading to Improved distinction resolution and enhanced visualization

Return on the technique preset interface. The option standing alterations into Uninstalled. The uninstalling operate is unique to interior customers.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

S. will have to give the Department by having an e-mail tackle if they've a single. The e-mail supplied may be utilized for Formal conversation While using the licensee. However email addresses are public file. If you don't would like to produce a personal address, remember to present the Office having an email address which can be created available to the public. To determine In case you are a licensee underneath Chapter 455, File.S., you should Click the link . Product or service Acceptance Accepts:

This guide might referring to info shielded by copyright or patents and will not Express any license underneath the patent rights or copyright of Mindray, or of Many others. Website page nine: Statement

The chapter provides the strategy to confirm most important function and efficiency of products. This is certainly only employed for reference, not preventive execution. Operate examining and testing of the element shall be performed by Mindray provider engineers as well as user collectively. Page 66: Standard Examination

Cookies are very important to the right performing of the web page. To boost your working experience, we use cookies to remember log-in information and provide protected log-in, collect figures to enhance web site functionality, and produce content tailor-made in your pursuits.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Performance Take a look at 5.5.1 Examination Approach Resolution Detection depth Geometric Place Precision Blackout area exam File the Test images five.five.2 Exam Articles The graphic used Here's just for reference, stick with the graphic outcome in the actual Observe: circumstance. Requirements: Show: set the contrast and brightness in the scientific application benefit (or perhaps the default standing) Operation environment: dark place, simulating the medical software environment. Website page seventy six In ailment that the transverse resolution testing targets are horizontally displayed, history the nominal length of two targets which can be Plainly acknowledged. Repeat the operation previously mentioned with the transverse resolution tests targets at other depths. As demonstrated in figure beneath. Axial resolution ... Website page seventy seven When using the convex probe, hold the transverse resolution screening targets to notice: be exhibited near the midline. When using a linear probe with steer function, do not activate the steer operate when execute the transverse resolution check. Zoom within the location where by the targets Positioned if needed. The diameter in the target issue at a particular depth is equivalent for the transverse resolution in the depth. Web site 78 five.

Mindray respects your privacy. We use cookies for several different needs, including Web-site performance, enhancing your encounter of our Web page, creating integration with social media marketing and aiding focus on our promotion.

five.2.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Examination Phase: Do adjustments as the best way in screening the maximum depth. Document the space by 20mm Every single section about the longitudinal targets line using the measurement caliper; Choose the worth with the best error (to 20mm), compute the precision using the system beneath The measurement caliper ought to be positioned for the upper fringe of the focus on, Take note:... Site seventy nine Transverse geometric positioning accuracy  Examination Phase: Protect the scan floor in the phantom with water or couple gel, gently Get in touch with the probe While using the scan floor Modify the depth, earning the transverse targets to get shown within the picture. Adjust the main target stage for being posited beside the transverse targets (the standard is not very clear) Regulate parameters like achieve, TGC, generating Just about every transverse targets to get Evidently shown. Site eighty 5.five.two.4 Blackout Area Exam Action: Include the scan surface of your phantom with h2o or couple gel, Carefully Make contact with the probe Along with the scan floor Modify the depth at Dp50rb a reduced benefit, and set the main target at the nearest destination to the scan area. Decrease the worth of parameters like AP, Gain till the history sound just can be found. Website page 81: Program Up grade And Servicing

Leave a Reply

Your email address will not be published. Required fields are marked *